WY5883 Multi-standard digital TV signal generator
WY8602A Series Multi Standard TV Pattern Generator
WY5418A Multi Standard Pattern Generator
WY2288 Digitally RF Millivolt Meter/Low Power Meter(200Hz-1.5GHz)
HFJ-8G RF Millivolt Meter (100Hz-1.5GHz)
WY2851D Digitel Q Meter(50kHz~50MHz)
WY2852D Digitel Q Meter(1kHz~70MHz)
 
 
 

 
WY2858 Dielectric Constant Measuring equipment( LCR method)

WY2855 dielectric constant measuring equipment consists of a high frequency impedance analyzer, test fixture and standard dielectric samples. So the high frequency dielectric loss angle tangent(D) and dielectric constant(ε) of the insulating material can be measures. It meets Chinese standard GB/T 1409-2006 , America standard ASTM D150 and IEC60250.
The operating frequency range of WY2858 is from 20Hz1MHz. So the change of the relative dielectric constant and dielectric loss angle tangent can be measured within the operating frequency range.
The test fixture is made by flat capacitors. The stuff to be tested is generally clamp by the plate capacitors. It should use a impedance analyzer meter as indicator instrument. To measure dielectric constant and loss of insulation material, first we use the device to get the result from Dielectric loss and Capacitance (Cp). The procedures of that is to measure the difference of that the one been put in the plate capacitor and the one in the outside.

1 Features:
1.1 The resolution of the high frequency impedance analyzer capacitance is 0.00001 pF and 6-Dielectric loss display. It can guarantee the accuracy and repeatability of the dielectric constant and dielectric loss angle tangent.
1.2 The measurement range of the dielectric constant is from 1~ 105

2 Specificution:
2.1 Character ofεand D
2.1.1 The measurement about the change of the solid insulating material ‘s εand D in 20Hz~1MHz.
2.1.2 εand D measuring range : ε: 1~ 105 , D:0.1~0.00005
2.1.3 ε and D measuring accuracy (10kHz), ε±2,D:±5%±0.0001
2.2 High frequency impedance measuring analyzer and digital electric bridge

Type

WY2817

WY2818A


frequency range

100Hz100kHz

(6 frequency points)

Accuracy:±0.05%

20Hz1MHz

digital synthesis

Accuracy:±0.02%


Capacitance measuring range

0.0001pF99.999mF

5-digit significant display

0.00001pF9.99999F

6-digit significant display

Fundamental error of capacitance measurement

±0.05%

±0.05%

Dielectric loss range

0.0001~9.9999

5-digit significant display

0.00001~9.99999

6-digit significant display

2.3 WY916 dielectric constant test fixture (It has protective electrode)
2.3.1 The size of the flat capacitor pole piece:Φ38mm and Φ50mm  (two kinds of option)
2.3.2 The gap adjustable range and resolution of the flat capacitor:08mm,±0.001mm
2.3.3 The plug gap: It can adapt for the electric bridge four-terminal


2.3.4 Heating and temperature-controlled device (It is the option device) can control the highest 200 and the accuracy can be 1.


2.4 WY918 precision dielectric constant test fixture can offer four diameters test electrode. It can accurate measure the specimen whose diameter is 10~56mm,and thickness is less than10mm. The test inductors can set as touched electrode method, membrane electrode method and untouched method to fit the test for soft material, irregular surface samples and membrane material.

2.4.1 Micrometer heads resolution: 10 μm

2.4.2 Maximum withstand voltage: ±42Vp(AC+DC)

2.4.3 cable length:1m

2.4.4 Maximum operating frequency: 30MHz

2.5 High frequency dielectric samples (It is the option device)

The verification department provides high frequency dielectric loss measuring meter with high frequency standard dielectric samples in the present high frequency dielectric material verification system. The samples are made of artificial sapphire, quartz glass, alumina ceramic, PTFE (polytetrafluoroethylene), epoxy material and so on. The samples are Φ50mm and 12mm thick.

You can order it as needed in order to ensure the repeatability and accuracy of the test inductors.

2.6 The configuration of WY2858 dielectric constant measuring fixture

Configuration type

Universal type

Standard type

Precise type

The frequency range of bridge

100Hz100kHz

accuracy:±0.02%

50Hz1MHz

accuracy: ±0.02%

50Hz1MHz

accuracy:±0.02%


Configuration model

WY2817

digital electric bridge+WY916B test fixture

WY2818

high frequency impedance analyzer+WY916B three-electrode test fixture

WY2818

high frequency impedance analyzer+WY918 Precise test fixture

Dielectric constant range

110000

accuracy: ±5%

150000

accuracy: ±2%

150000

accuracy: ±2%

Dielectric loss range

0.00019.9999

4-digit significant display

0.000019.99999

6-digit significant display

0.000019.99999

6-digit significant display